Fire curtains
Categories
- Strip curtains (3)
- Fire and security doors (13)
- Fire doors (24)
- Fire curtains (12)
- E-class fire curtains (3)
- Fire curtains EI classes (2)
- EW-class fire curtains (4)
- Brandjalousi (2)
- Smokescreen (1)
- Fire sliding doors (5)
- DAN-matic (12)
- Hinged doors (12)
- High Speed doors / rulleporte (14)
- Cold room doors (29)
- Profile doors (32)
- Profile doors for fire (32)
- Smoke ventilation (4)
- security doors (9)
- Sliding gates (16)
- Steel doors (142)
- Swing doors (8)
- Thermo doors (2)
- Vertical sliding doors (6)
Why choose fire curtains?
DAN-doors' fire curtains range from a certification of 30 minutes to a classification of up to 240 minutes. The fire curtains are certified in EI, EW or E-class respectively.
EI-CLASS FIRE Curtains highest fire safety for all purposes
WithEI-class fire curtains, you get a solution that meets the strictestsafety requirements. EI curtains consist of 3 or 5 layers of reinforced glass fiber with insulating material and provide the highestlevel of protection against the spread of fire and smoke. EI curtains effectively reduce heat on the opposite side and can therefore be used in connection withevacuation routesand to protect against damage caused by heat and smoke.
The curtains are prepared for external ABA/ABDL signals so that it automatically runs down in case of fire.
The fire curtain has a discreet design and the guide rails are normally available in steel or in RAL colours 7035, 9002 or 9010. They can optionally be supplied painted in custom RAL colours to integrate the system into the overall design of the environment in which it is installed.
FIRE Curtains EW-CLASSEN high fire safety in a lightweight construction
EW class fire curtains rank among the safest on the market and are used to prevent the spread of fire between buildings, floor sections and fire zones. The curtains are made of 2-layer reinforced glass fabric and are laminated with aluminium foil, which provides heat reduction on the opposite side and protection against radiant heat.
The fire curtains are prepared for external ABA/ABDL signals, so that it automatically runs down in case of fire.
The system is available both wall-mounted and niche-mounted and has a lightweight construction that makes it easy to install. The curtains require a minimum of space and can be installed in locations with very low installation heights, making it suitable for locations where height can be a challenge.
FIRE CURTAINS E-CLASS Effective solution to stop the spread of fire
Class E fire curtains are used to prevent the spread of fire between buildings, floor sections and fire zones.
They are particularly suitable for securing areas that do not require personal protection, as the curtains can provide protection for up to 240 minutes, but do not have heat reduction on the opposite side.
The system is available both wall-mounted and niche-mounted and is easy to install. It requires minimal space and can be installed in locations with very low installation heights, making it suitable for locations where height can be a challenge.
SMOKE CURTAINS - Effective solution to prevent the spread of smoke
Smoke curtains D120 are used to control the spread of smoke in the event of a fire, thus creating better escape conditions in the building.
The smoke curtains consist of a technologically advanced fire- and resistance-resistant woven fabric, which is mounted in a steel box that is easily integrated into the building structure.
The curtains are tested and certified according to the EU standard EN-12101-1, which approves them to stop and control the spread of smoke and thus improve escape route safety in buildings.
The smoke curtains are prepared for external ABA/ABDL signals so that they automatically close in the event of a fire.
FIRE SHUTTER Also approved for food and pharmaceutical industries
This fire shutter is approved for 60 minutes.
The fire blind has a built-in ABDL central and can also be prepared for signal from external ABA systems. In this way, the fire blind automatically shuts down, protecting against further fire development.
The fire shutter consists of guide rails in galvanised steel and a top profile in galvanised steel.
Guide rails and Venetian blind roller can be covered with lacquered steel sheets.
Fire curtains
High fire safety
Customized smoke ventilation
Certified solutions
Insulating material
Fire curtains - FAQ
EI fire curtains represent the absolute highest level of safety, as you can pass very close to the curtain, which is crucial for escape routes.
This is followed by EW curtains, which also have heat reduction on the opposite side, but the curtain itself can get very hot, so a little distance is required when passing.
E-curtains do not have heat reduction on the opposite side, but provide up to four hours of protection, making them an attractive solution for protecting equipment and buildings.
















Shall we help you?
If you need advice and help finding the right product for your needs, you are always welcome to contact us.
We are experts in access solutions of all kinds for industry, and we are always ready to have a no-obligation chat.
Call us today or send us an email and we'll get back to you as soon as possible. We look forward to hearing from you and helping you find the right solution.